HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2_1
HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2_2HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2_3HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2_4HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2_5

HD 2114P.0, HD 2114P.2, HD 2134P.0, HD 2134P.2 – Portable Micro Manometer – Thermometer for Pitot Tubes

The HD2114P.0 and HD2114P.2, HD2134P.0 and HD2134P.2 are portable micromanometers
for Pitot tubes with large LCD display. They are used to perform measurements in air conditioning,
heating and ventilation.
They measure the differential pressure measured by Pitot tube connected to the inputs of the
instrument and achieve the speed and air fl ow in ducts or vents; also measure temperature
with thermocouple K probe.
The instruments can be used as thermometers and can be employed with any kind of thermocouple
K sensor if a standard miniature connector is used.
The HD2114P.2 and HD2134P.2 instruments are dataloggers. They store up to 36,000 samples
which can be transferred from the instrument to a PC connected via the RS232C and USB
2.0 serial ports. The storing interval, printing and baud rate can be confi gured using the menu.
They are also equipped with an RS232C serial port which can transfer in real time the acquired
measurements to a PC or to a portable printer.
The Max, Min and Avg function calculates the maximum, minimum or average values. Other
functions include: the relative measurement REL, the HOLD function, and the automatic turning
off which can be excluded. The instruments have IP66 protection degree.

Request a quote

Send me a price quotation for the following products:

Product Description

The HD2114P.0 and HD2114P.2, HD2134P.0 and HD2134P.2 are portable micromanometers
for Pitot tubes with large LCD display. They are used to perform measurements in air conditioning,
heating and ventilation.
They measure the differential pressure measured by Pitot tube connected to the inputs of the
instrument and achieve the speed and air fl ow in ducts or vents; also measure temperature
with thermocouple K probe.
The instruments can be used as thermometers and can be employed with any kind of thermocouple
K sensor if a standard miniature connector is used.
The HD2114P.2 and HD2134P.2 instruments are dataloggers. They store up to 36,000 samples
which can be transferred from the instrument to a PC connected via the RS232C and USB
2.0 serial ports. The storing interval, printing and baud rate can be confi gured using the menu.
They are also equipped with an RS232C serial port which can transfer in real time the acquired
measurements to a PC or to a portable printer.
The Max, Min and Avg function calculates the maximum, minimum or average values. Other
functions include: the relative measurement REL, the HOLD function, and the automatic turning
off which can be excluded. The instruments have IP66 protection degree.

TECHNICAL SPECIFICATIONS OF THE INSTRUMENTS
Instrument
Dimensions (Length x Width x Height) 185x90x40mm
Weight 470g (complete with batteries)
Materials ABS, rubber
Display 2×4½ digits plus symbols
Visible area: 52x42mm
Operating conditions
Operating temperature -5…50°C
Storage temperature -25…65°C
Working relative humidity 0…90%RH without condensation
Protection degree IP66
Power supply

Batteries 4 1.5V type AA batteries
Autonomy 200 hours with 1800mAh alkaline batteries
Power absorbed with instrument off 20μA
Mains – models HD2114P.2 and HD2134P.2 Output mains adapter 12Vdc / 1000mA
Measuring unit °C – °F – Pa – mbar – mmH2O – PSI – m/s
km/h – ft/m – mph – knot – l/s – m3/h – cfm
Security of memorized data Unlimited, independent of battery
charge conditions
Time
Date and time in real time
Accuracy 1min/month max drift
Measured values storage – models HD2114P.2 and HD2134P.2
Type 2000 pages containing 18 samples each
Quantity 36000 samples
Storage interval 1,5,10,15,30 sec.;
1,2,5,10,15,20,30 min.; 1 hour
Serial interface RS232C – models HD2114P.2 and HD2134P.2
Type RS232C electrically isolated
Baud rate Can be set from 1200 to 38400 baud
Data bit 8
Parity None
Stop bit 1
Flow Control Xon/Xoff
Serial cable length Max 15m
Print interval Immediate or 1,5,10,15,30 sec.;
1,2,5,10,15,20,30 min.; 1 hour
USB interface – models HD2114P.2 and HD2134P.2
Type 1.1 – 2.0 electrically isolated
Connections
Pressure inputs 2 quick couplings Ø 5mm
TC type K Temperature input 2-pole female polarized standard
miniature connector
Serial interface – models
HD2114P.2 and HD2134P.2 8-pole MiniDin connector
USB interface – models
HD2114P.2 and HD2134P.2 MiniUSB type B connector
Mains adapter – models
HD2114P.2 and HD2134P.2 2-pole connector (positive at centre)
Measurement of pressure, wind speed and fl ow rate calculated by the internal sensor, and

temperature measured using thermocouple K.

Thermocouple probes accuracy:
Tolerance of a type of thermocouple corresponds to the maximum acceptable shift from
the e.m.f. of any thermocouple of that type, with reference junction at 0°C. The tolerance
is expressed in degrees Celsius, preceded by the sign. The percentage tolerance is given by
the ratio between the tolerance expressed in degrees Celsius and the measurement junction
temperature, multiplied by one hundred.

AS-12

Class 3, for T, E, K and N thermocouples when the thermocouples have to comply at the same
time with the limits of Class 3 and those of Class 1 and/or Class 2.
USB and RS232 data connection
Please see the diagram at page VA-4
A The HD21x4P.2 instruments use a new serial miniUSB port HD type (Human Interface
Device). It is not necessary to install any driver for connecting the instrument
to the PC with the USB cable type A – MiniUSB type B coded CP23.
C The port equipped with the MiniDIN connector is an RS232C type that can be
used for the connection to the PC or to the HD40.1 printer by using the cable
HD2110CSNM.
ORDERING CODES
HD2114P.0: The kit consists of the HD2114P.0 with 20mbar full scale and thermocouple K
input, 4 1.5V alkaline batteries, operating manual, case. The Pitot tubes have to be
ordered separately.
HD2114P.2: The kit consists of the HD2114P.2 datalogger with 20mbar full scale and thermocouple
K input, 4 1.5V alkaline batteries, operating manual, case and DeltaLog9 software.
The Pitot tubes and cables have to be ordered separately.
HD2134P.0: The kit consists of the HD2134P.0 with 200mbar full scale and thermocouple
K input, 4 1.5V alkaline batteries, operating manual, case. The Pitot tubes have to be
ordered separately.
HD2134P.2: The kit consists of the HD2134P.2 datalogger with 200mbar full scale and
thermocouple K input, 4 1.5V alkaline batteries, operating manual, case and DeltaLog9
software. The Pitot tubes and cables have to be ordered separately.
HD2110CSNM: 8-pole connection cable MiniDin – Sub D 9-pole female for RS232C.
CP23: Connection cable USB 2.0 connector type A – Mini USB type B.
DeltaLog9: Software for download and management of the data on PC using Windows operating
systems.
PW: Extension with male-female standard miniature connectors to connect the Pitot tube’s
thermocouple K to the instrument, length 2m.
SWD10: Stabilized power supply at 230Vac/12Vdc-1000mA mains voltage.
HD40.1: On request, portable, serial input, 24 column thermal printer, 58mm paper width.
K type thermocouple probes
Any thermocouple probe with standard miniature connector available on the price list can be
connected to these instruments.
Please see page AS-17.

 

 