HD 2107_1
HD 2107_2HD 2107_3

HD 2107.1, HD 2107.2, HD 2127.1, HD 2127.2 – Thermometers Sensors: Pt100, Pt1000

HD2107.1 and l’HD2107.2 are portable instruments equipped with large LCD display
fitted with one input. HD2127.1 and HD2127.2 are instruments fitted with two inputs.
They measure temperature by means of immersion, penetration, contact or air probes.
Their sensor can be Pt100 with 3 or 4 wires, Pt1000 with 2 wires. They have centesimal
resolution in the range ± 199.99°C, decimal in the rest of the range.

Request a quote

Send me a price quotation for the following products:

Product Description

HD2107.1 and l’HD2107.2 are portable instruments equipped with large LCD display
fitted with one input. HD2127.1 and HD2127.2 are instruments fitted with two inputs.
They measure temperature by means of immersion, penetration, contact or air probes.
Their sensor can be Pt100 with 3 or 4 wires, Pt1000 with 2 wires. They have centesimal
resolution in the range ± 199.99°C, decimal in the rest of the range.
Probes are equipped with an automatic recognition module: factory calibration data are
stored inside.
The instruments HD2107.2 and HD2127.2 are data loggers; they store up to 80.000
samples which can be transferred into a PC connected to the instrument through the
serial ports RS232C and USB 2.0. It is possible to configure the storage interval, the
printing and the baud rate by the menu.
All models are equipped with RS232C serial port and are able to transfer the acquired
measures, in real time, to a PC or a portable printer.
Functions Max, Min and Avg calculate maximum, minimum and average values.
Further functions are: REL relative measure, HOLD and automatic switching-off system,
excludable.
Instruments have IP66 protection degree.

TECHNICAL SPECIFICATIONS OF THE INSTRUMENTS
Instrument
Dimensions
(Length x Width x Height) 185x90x40mm
Weight 470g (complete with batteries)
Materials ABS, rubber
Display 2×4½ digits plus symbols
Visible area: 52x42mm
Operating conditions
Operating temperature -5 … 50°C
Storage temperature -25 … 65°C
Working relative humidity 0 … 90% RH, no condensation
Protection degree IP66
Power supply
Batteries 4 Batteries 1.5V type AA
Autonomy 200 hours with 1800mAh alkaline batteries
Current consumption with
instrument off 20μA
Main 12Vdc / 1000mA Output main adapter
Unit of measurement °C – °F – °K
Security of stored data Unlimited, independent of battery charge conditions
Time
Date and time In real time
Accuracy 1min/month max drift
Measured values storage
model HD2107.2
Type 2000 pages containing 40 samples each
Quantity Total of 80000 samples
Storage interval
can be selected between 1,5,10,15,30 s.; 1,2,5,10,15,20,30 min.;1 hour
model HD2127.2
Type 2000 pages containing 16 pairs of samples each
Quantity Total of 32000 samples (channel A + channel B)
Storage interval
can be selected between 1,5,10,15,30 s.; 1,2,5,10,15,20,30 min.;1 hour
Serial interface RS232C
Type RS232C galvanic isolated
Baud rate can be set from 1200 to 38400 baud
Data bit 8
Parity None
Stop bit 1
Flow Control Xon/Xoff
Serial cable length Max 15m
Print interval Immediate or selectable between:
1,5,10,15,30 s.; 1,2,5,10,15,20,30 min.; 1 hour
USB interface – model HD2107.2, HD2127.2
Type 1.1 – 2.0 galvanic isolated
Connections
Input module for the probes 8-pole male DIN45326 connector
RS232C serial interface 8-pole MiniDin connector
USB interface Type B MiniUSB connector
Mains adapter 2-pole connector (positive at centre)
Measurement of temperature by Instrument
Pt100 measurement range -200…+650°C
Pt1000 measurement range -200…+650°C
Resolution 0.01°C in the range ±199.99°C
0.1°C in the remaining range
Instrument Accuracy ±0.01°C
Drift after 1 year 0.1°C/year

A To the portable data loggers of the series HD21….2 a serial port mini USB type HID
(Human Interface Device) has been inserted.
For the connection to a PC with the cable USB type A – MiniUSB type B code CP23, it is
not necessary to load any driver USB.
B For the connection of the models HD21….1 to the USB port of a PC, is necessary the
USB/serial converter C.206. The converter is supplied with its own drivers which must
be installed before the connection of the converter to the PC.(see details in the Cd-Rom
supplied with the converter).
C The port with the miniDin connector in all included models, is a serial port type RS232C.
The serial port RS232C of a PC or the printer HD40.1 can be connected by the cable
HD2110CSNM.

ORDERING CODES
HD2107.1: The kit consists of instrument HD2107.1, 4 per 1.5V alkaline batteries,
instruction manual, case and DeltaLog9 software. Probes and cables have to be
ordered separately.
HD2107.2: The kit consists of instrument HD2107.2 data logger, 4 per 1.5V alkaline
batteries, instruction manual, case and DeltaLog9 software. Probes and cables
have to be ordered separately.
HD2127.1: The kit consists of instrument HD2127.1, 4 per 1.5V alkaline batteries,
instruction manual, case and DeltaLog9 software. Probes and cables have to be
ordered separately.
HD2127.2: The kit consists of instrument HD2127.2 data logger, 4 per 1.5V alkaline
batteries, instruction manual, case and DeltaLog9 software. Probes and cables
have to be ordered separately.
HD2110CSNM: 8-pole connection cable MiniDin – Sub D 9-pole female for RS232C.
C.206: Cable for instruments of the serie HD21…1 to connect directly to USB input of PC.
CP23: Connection cable USB 2.0 connector type A – Mini USB type B.
DeltaLog9: Software for download and management of the data on a PC using Windows
operating systems.
SWD10: Stabilized power supply at 230Vac/12Vdc-1000mA mains voltage.
HD40.1: Upon request, portable, serial input, 24 column thermal printer, 58mm paper
width. Use cable HD2110CSNM (option).

Temperature probes equipped with SICRAM module
TP472I: Immersion probe, Wire Wound Pt100 sensor. Stem Ø 3 mm, length 300 mm.
Cable 2 meters long.
TP472I.0: Immersion probe, Thin Film Pt100 sensor. Stem Ø 3 mm, length 230 mm.
Cable 2 meters long.
TP473P.I: Penetration probe, Wire Wound Pt100 sensor. Stem Ø 4mm, length 150 mm.
Cable 2 meters long.
TP473P.0: Penetration probe, Thin Film Pt100 sensor. Stem Ø 4mm, length 150 mm.
Cable 2 meters long.
TP474C.I: Contact probe, Wire Wound Pt100 sensor. Stem Ø 4mm, length 230mm,
contact surface Ø 5mm. Cable 2 meters long.
TP474C.0: Contact probe, Thin Film Pt100 sensor. Stem Ø 4mm, length 230mm, contact
surface Ø 5mm. Cable 2 meters long.
TP475A.0: Air probe, Thin Film Pt100 sensor. Stem Ø 4mm, length 230mm. Cable 2
meters long.
TP472I.5: Penetration probe, Thin Film Pt100 sensor. Stem Ø 6mm, length 500 mm.
Cable 2 meters long.
TP472I.10: Penetration probe, Thin Film Pt100 sensor. Stem Ø 6mm, length 1000mm.
Cable 2 meters long.
TP49A.0: Immersion probe, Thin Film Pt100 sensor. Stem Ø 2.7mm, length 150mm.
Cable 2 meters long. Aluminium handle.
TP49AC.0: Contact probe, Thin Film Pt100 sensor. Stem Ø 4 mm, length 150mm. Cable
2 meters long. Aluminium handle.
TP49AP.0: Penetration probe, Thin Film Pt100 sensor. Stem Ø 2.7mm, length 150mm.
Cable 2 meters long. Aluminium handle.
TP875.I: Globe thermometer Ø 150 mm with handle. Wire Wound Pt100 sensor complete
of SICRAM module. Cable 2 meters long.
TP876.I: Globe thermometer Ø 50 mm with handle. Wire Wound Pt100 sensor complete
of SICRAM module. Cable 2 meters long.
TP87.0: Immersion probe, Thin Film Pt100 sensor. Stem Ø 3 mm, length 70 mm. Cable
2 meters long.
TP878.0: Contact probe for solar panels. Thin Film Pt100 sensor. Cable 2 meters long.
TP878.1.0: Contact probe for solar panels. Thin Film Pt100 sensor .Cable 5 meters long
TP879.0: Penetration probe for compost. Thin Film Pt100 sensor. Stem Ø 8 mm, length
1000mm. Cable 2 meters long.
Temperature probes without SICRAM module
TP47.100.0: Immersion probe, Thin Film Pt100 sensor probe. Stem Ø 3 mm, length
230mm. 4 wires connection cable with connector, 2 meters long.
TP47.1000.0: Thin Film Pt1000 sensor immersion probe. Stem Ø 3 mm, length 230mm.
2 wires connection cable with connector, 2 meters long.
TP47: Only connector for probe connection without SICRAM module: direct 3 and 4 wires
Pt100, 2 wires Pt1000.
TP87.100.0 Immersion probe, Thin Film Pt100 sensor. Stem Ø 3 mm, length 70mm.
Cable 2 meters long. 4 wires connection cable with connector 1 meter long.
TP87.1000.0 Immersion probe, Thin Film Pt100 sensor. Stem Ø 3 mm, length 70mm.
Cable 2 meters long. 2 wires connection cable with connector 1 meter long.

 

Download

Manuals and Brochures here.  

HD2107_1_2.pdf

Reviews

There are no reviews yet.

Be the first to review “HD 2107.1, HD 2107.2, HD 2127.1, HD 2127.2 – Thermometers Sensors: Pt100, Pt1000”

Your email address will not be published. Required fields are marked *